Lucene search

K
MoxaOncell G3150-hspa-t Firmware

6 matches found

cve
cve
added 2019/07/03 4:15 p.m.54 views

CVE-2018-11422

Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands (including devic...

9.8CVSS9.3AI score0.00239EPSS
cve
cve
added 2019/07/03 3:15 p.m.49 views

CVE-2018-11426

A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functions except for password change.

9.8CVSS9.6AI score0.00442EPSS
cve
cve
added 2019/07/03 4:15 p.m.48 views

CVE-2018-11420

There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423.

9.8CVSS7.8AI score0.00433EPSS
cve
cve
added 2019/07/03 4:15 p.m.45 views

CVE-2018-11423

There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420.

7.8CVSS8.7AI score0.00433EPSS
cve
cve
added 2019/07/03 3:15 p.m.44 views

CVE-2018-11427

CSRF tokens are not used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior, which makes it possible to perform CSRF attacks on the device administrator.

8.8CVSS8.5AI score0.00141EPSS
cve
cve
added 2019/07/03 4:15 p.m.43 views

CVE-2018-11421

Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to re...